iglide® Q2 - Material data

Materials table

General featuresUnitiglide® Q2test method
Densityg/cm31.46
Colobeige-brown
Max. moisture absorption at 73°F/50% R. H.Wt.-%1.1DIN 53495
Max. moisture absorptionWt.-%4.6
Coefficient of surface friction, dynamic, against steelµ0.22-0.42
P x v value, max. (dry)psi x fpm19,500
Mechanical properties
Modulus of elasticitypsi1,214,000DIN 53457
Tensile strength at 68° Fpsi 34,810DIN 53452
Compressive strengthpsi18,850
Maximum recommended surface pressure (68° F)psi17,400
Shore D-hardness80DIN 53505
Physical and thermal properties
Upper long-term application temperature°F266
Upper short-term application temperature°F392
Lower application temperature°F-40
Thermal conductivity[W/m x K]0.24ASTM C 177
Coefficient of thermal expansion (at 73°F)[K-1 x 10-5]8DIN 53752
Electrical properties
Specific volume resistanceΩcm> 1013DIN IEC 93
Surface resistanceΩ> 1011DIN 53482
Plastic Bushings Permitted p x v values
Plastic Bushings Permitted p x v values

Permitted p x v values

Deformation under load and temperatures

Compressive Strength

Permitted surdace speeds

fpmRotaryOscillatingLinear
Constant197137787
Short-term393275984

Temperatures

iglide® Q2Application temperature
Lower-40°C
Upper, long-term+266°F
Upper, short-term+392°F
Additional axial securing+176°F
Temperature limits for iglide® Q2

Recommended max permissible static surface
Recommended maximum permissible static surface pressure of iglide® Q2 as a result of the temperature
Coeff of friction as a function of the running speed
Coefficients of friction dependent on the load
Coefficients of friction dependent on the shaft surface
Wear, rotating application with different shaft materials
Wear with various shaft materials in the rotating operation
Wear with different shaft materials, oscillating and rotating movement

Chemical resistance

MediumResistance
Alcohols+
Hydrocarbons, chlorinated+
Greases, oils, without additives+
Fuels+
Weak acids0 to -
Strong acids-
Weak alkaline+
Strong alkaline0
+ resistant | 0 conditionally resistant | - non-resistant
glide® Q2 chemical resistance
All specifications at room temperature [+68 °F] iglide® Q2 chemical resistance

Radioactive rays

UV-resistant

Vacuum

Electrical properties

Specific volume resistanceSurface resistance
> 1013 Ωcm> 1013 Ω

Effect of moisture absorption on iglide® Q2 plastic bushings
Effect of moisture absorption on iglide® Q2 plastic bushings

Installation tolerances

Diameter d1 [mm]Shaft h9 [mm]iglide® Q2 E10 [mm]Housing H7 [mm]
Up to 30 - 0,025+0,014 +0,0540 +0,010
> 3 bis 60 - 0,030+0,020 +0,068 0 +0,012
> 6 bis 100 - 0,036+0,025 +0,0830 +0,015
> 10 bis 180 - 0,043+0,032 +0,1020 +0,018
> 18 bis 300 - 0,052 +0,040 +0,1240 +0,021
> 30 bis 500 - 0,062+0,050 +0,1500 +0,025
> 50 bis 800 - 0,074 +0,060 +0,1800 +0,030
> 80 bis 1200 - 0,087+0,072 +0,2120 +0,035
> 120 bis 1800 - 0,100+0,085 +0,2450 +0,040
Table 07: Important tolerances for iglide® Q2 plastic bushings according to ISO 3547-1 after the press-in