Change Language :
The drylin® WKMEX measuring system takes very little installation space. The sensor head is integrated in the carriage (total height 36 mm). Three sensor options are available, two are compatible with TTL Line Driver. For guiding the signal cable, the igus® e-chains® of the series 045.10.028.0 is recommended. Length specific article numbers, see:
system E2 micro
system E-Z Chain®
Ready-to-fit measuring device for external signal output
At 4 edge triggering (setting parameters of the display or control, for example, IW4) and +68°F ambient temperature: Resolution: ±(0.025 + 0.02 · L) L = measuring length in meters; Repeatability: ±0.025 mm
At 1 edge triggering (setting parameters of the display or control, for example, IW1) and +68°F ambient temperature: Resolution: ±(0,1 + 0,02 · L) L = measuring length in meters; Repeatability: ±0,025 mm
Small sensor with integrated unit
Output signals:Push-pull continuous short circuit proof with inverted signals (A. A/, B, B/, Z, Z/)
Sensor type
Nominal voltage
Output power
max. length of signal cable
00
10 - 30 V
10 - 30 V
30 m
01
10 - 30 V
5 V (TTL Line Driver)
50 m
11
5 V
5 V (TTL Line Driver)
10 m
specifications
Measuring principle
Incremental
Repeat accuracy
± 1 increment
Pole division
5 mm
Sensor housing
Zinc die cast
Protection class
IP67
Operating temperature
14 … +158° F
Max. humidity
95%, non-condensing
Max. speed
4,0 m/s
VDC power supply
5 VDC or 10 to 30 VDC
Current draw
5 VDC: max. 200 mA
10 to 30 VDC: max. 150 mA
Internal evaluation electronics
Internal evaluation electronics
Output power
5 V-TTL line driver or 10 to 30 V_HTL
Source tracks
A, A‘,B, B‘, Z, Z‘
Max. cable length
Max. cable length 5V/5V-TTL = 10 m
10-30V/10-30V = 30 m
10-30V/5V-TTL = 50 m
Max. permissible distance from magnetic tape
2,0 mm
Connection method
Open cable ends